NewVision upstream

Pump 338-400 vs Pump 513-6000a

Summary

  • Pump 513-6000a has the higher Shut-in pressure per stage at 60 Hz (+102%): 19.47 psi versus 9.62 psi for Pump 338-400.
  • Pump 513-6000a has the higher Max shaft thrust (+77%): 26.5 lb versus 15 lb for Pump 338-400.
  • Pump 513-6000a has the higher Shaft cross-section area (+156%): 0.7854 in² versus 0.3068 in² for Pump 338-400.

Overview

Parameter
Pump 338-400
Pump 513-6000a
Object type
ESP pump
ESP pump

Pump

Parameter
Pump 338-400
Pump 513-6000a
Series
338
513
Nominal rate at 60 Hz, bpd
400
6000a
Stage type
Radial
Mixed
Shaft diameter, in
0.625
1
Shaft cross-section area, in²
0.3068
0.7854
Max shaft thrust, lb
15
26.5
Shut-in pressure per stage at 60 Hz, psi
9.62
19.47
Design with Pump 338-400Design with Pump 513-6000a