NewVision upstream

Pump 338-550 vs Pump 675-6500

Summary

  • Pump 675-6500 has the higher Max shaft thrust (+613%): 112 lb versus 15.7 lb for Pump 338-550.
  • Pump 675-6500 has the higher Shut-in pressure per stage at 60 Hz (+442%): 51.86 psi versus 9.57 psi for Pump 338-550.
  • Pump 675-6500 has the higher Shaft cross-section area (+156%): 0.785 in² versus 0.3068 in² for Pump 338-550.

Overview

Parameter
Pump 338-550
Pump 675-6500
Object type
ESP pump
ESP pump

Pump

Parameter
Pump 338-550
Pump 675-6500
Series
338
675
Nominal rate at 60 Hz, bpd
550
6500
Stage type
Radial
Mixed
Shaft diameter, in
0.625
1
Shaft cross-section area, in²
0.3068
0.785
Max shaft thrust, lb
15.7
112
Shut-in pressure per stage at 60 Hz, psi
9.57
51.86
Design with Pump 338-550Design with Pump 675-6500