NewVision upstream

Pump 338-900 vs Pump ESP B 400-3000

Summary

  • Pump ESP B 400-3000 has the higher Max shaft thrust (+109%): 33.3 lb versus 15.9 lb for Pump 338-900.
  • Pump ESP B 400-3000 has the higher Shut-in pressure per stage at 60 Hz (+85%): 17.6 psi versus 9.49 psi for Pump 338-900.
  • Pump ESP B 400-3000 has the higher Shaft cross-section area (+92%): 0.589 in² versus 0.3068 in² for Pump 338-900.

Overview

Parameter
Pump 338-900
Pump ESP B 400-3000
Object type
ESP pump
ESP pump

Pump

Parameter
Pump 338-900
Pump ESP B 400-3000
Series
338
ESP B 400
Nominal rate at 60 Hz, bpd
900
3000
Stage type
Radial
Mixed
Shaft diameter, in
0.625
0.866
Shaft cross-section area, in²
0.3068
0.589
Max shaft thrust, lb
15.9
33.3
Shut-in pressure per stage at 60 Hz, psi
9.49
17.6
Design with Pump 338-900Design with Pump ESP B 400-3000