NewVision upstream

400-500 vs 400-700 vs 400-950

Summary

  • Pump 400-950 has the higher Shut-in pressure per stage at 60 Hz (+8%): 15.27 psi versus 14.13 psi for Pump 400-500.
  • Pump 400-500 has the higher Shaft cross-section area (+21%): 0.3718 in² versus 0.3068 in² for Pump 400-950.
  • Pump 400-500 has the higher Shaft diameter (+10%): 0.688 in versus 0.625 in for Pump 400-950.

Overview

Parameter
Pump 400-500
Pump 400-700
Pump 400-950
Object type
ESP pump
ESP pump
ESP pump

Pump

Parameter
Pump 400-500
Pump 400-700
Pump 400-950
Series
400
400
400
Nominal rate at 60 Hz, bpd
500
700
950
Stage type
Radial
Radial
Radial
Shaft diameter, in
0.688
0.625
0.625
Shaft cross-section area, in²
0.3718
0.3068
0.3068
Shut-in pressure per stage at 60 Hz, psi
14.13
13.95
15.27
Design with Pump 400-500Design with Pump 400-700Design with Pump 400-950