NewVision upstream

Pump ESP B 400-1250 vs Pump ESPMIK8-2800

Summary

  • Pump ESPMIK8-2800 has the higher Shut-in pressure per stage at 60 Hz (+162%): 37.5 psi versus 14.32 psi for Pump ESP B 400-1250.
  • Pump ESPMIK8-2800 has the higher Shaft cross-section area (+125%): 1.0954 in² versus 0.487 in² for Pump ESP B 400-1250.
  • Pump ESPMIK8-2800 has the higher Shaft diameter (+50%): 1.181 in versus 0.787 in for Pump ESP B 400-1250.

Overview

Parameter
Pump ESP B 400-1250
Pump ESPMIK8-2800
Object type
ESP pump
ESP pump

Pump

Parameter
Pump ESP B 400-1250
Pump ESPMIK8-2800
Series
ESP B 400
ESPMIK8
Nominal rate at 60 Hz, bpd
1250
2800
Stage type
Radial
Mixed
Shaft diameter, in
0.787
1.181
Shaft cross-section area, in²
0.487
1.0954
Shut-in pressure per stage at 60 Hz, psi
14.32
37.5
Design with Pump ESP B 400-1250Design with Pump ESPMIK8-2800