NewVision upstream

Pump ESPMIK5-300 vs Pump ESPMIK6-1250

Summary

  • Pump ESPMIK6-1250 has the higher Shaft cross-section area (+86%): 1.0954 in² versus 0.589 in² for Pump ESPMIK5-300.
  • Pump ESPMIK6-1250 has the higher Shaft diameter (+36%): 1.181 in versus 0.866 in for Pump ESPMIK5-300.
  • Pump ESPMIK5-300 has the higher Shut-in pressure per stage at 60 Hz (+3%): 13.23 psi versus 12.9 psi for Pump ESPMIK6-1250.

Overview

Parameter
Pump ESPMIK5-300
Pump ESPMIK6-1250
Object type
ESP pump
ESP pump

Pump

Parameter
Pump ESPMIK5-300
Pump ESPMIK6-1250
Series
ESPMIK5
ESPMIK6
Nominal rate at 60 Hz, bpd
300
1250
Stage type
Mixed
Mixed
Shaft diameter, in
0.866
1.181
Shaft cross-section area, in²
0.589
1.0954
Shut-in pressure per stage at 60 Hz, psi
13.23
12.9
Design with Pump ESPMIK5-300Design with Pump ESPMIK6-1250